Live Help Estimator

Share this site:

share us on linkedin share us on twitter watch us on youtube join us on facebook

Polystyrene Sheet 2400 x 1200 x 75mm (eps70) (1 sheet = 2.88m²)

Products you may also need:

Gyproc Thermaline Basic Insulation Board 2400 x 1200 x 40mm

more details

Gyproc Thermaline Plus Insulation Board 2400 x 1200 x 55mm

more details

Gyproc Thermaline Super Insulation Board 2400 x 1200 x 50mm

more details

Gyproc Dri-wall adhesive 25kg

more details

Plasterboard 2400 x 1200 x 12.5mm Tapered Edge

more details
Polystyrene Sheet 2400 x 1200 x 75mm (eps70) (1 sheet = 2.88m²)

from £24.28

inc VAT

Price per Single sheet:

  • Up to 4: £22.48
  • 5-9 : £21.36
  • 10+ : £20.23

Product Code: 047/047/005
Enter Quantity:

All flooring panels are delivered to site wrapped in polythene. The panels should be stored in the original wrapping, under cover and protected from direct sunlight. Panels should be kept above ground level and out of contact with solvents and materials containing volatile organic compounds such as coal tar, pitch or timber recently treated with creosote.

Do not expose to naked flame or other ignition sources during storage or installation.

Ensure that the concrete sub-floor or suspended concrete floor is dry, smooth and level to within 5mm when measured with a 3m straight edge. Minor irregularities up to 10mm may be levelled with a motor levelling screed. Irregularities greater than this must be removed.

Where possible, electrical conduits, gas and water pipes or other services should be contained within ducts or channels within the concrete slab. Where this is not possible, the services may be accommodated within the thickness of the floor insulation provided they are securely fixed to the concrete slab. Water pipes must be pre-lagged with proprietary material and the floor insulation must be cut back to maintain at least 5mm clear air space between any insulated hot pipes.

For floors incorporating chipboard overlays, where access to the services is desirable, a duct may be formed by mechanically fixing to the floor timber bearers of the same thickness as the insulation to provide support for a chipboard cover. The duct should be as narrow as possible and not exceed the maximum chipboard spans recommended in BS7916:1998.

Any PVC sheathed cable should be run in conduit. The panels should be cut with a sharp knife to fit accurately around the services.
The Advantages

* Offers a range of solutions to the new building regulations
* Easy to handle and cut
* Thinner boards
* Long lasting efficient thermal insulation which will remain effective for the life of the building. Performance does not deteriorate with age
* British Board of Agreement certification on partial fill cavity and flooring insulation
* Simple to install without the need of special tools
* 100% recyclable
* Cost effective
* Completely CFC and HCFC free
* Thermal Value of 0.030 & 0.033 W/mK

RATING: StarStarStarStarStar
Andrew, Brighton

RATING: StarStarStarStarNo Star
chester, Farnham